FKK anti-freeze protection systems fit to every water boiler/heater systems to reduce by 25% power consumption.
Save over than 25% of power consumption compared to traditional ani-freeze protection systems.
The embedded heating plate effectively transfer heat to the plate and allow a power reduction by 25% compared to conventional system.
Moreover, since heat is efficiently transferred to the heating pipe, temperature of the heater body can now be lowered to 50 °c.
Safer the system also substantially improves the durability of the heater by lowering the temperature of the box.
Gas and oil water boiler/heater anti-freeze protection
Measurement of temperatures for standard 16 W and eco 12 W heater systems. Test performs during 12 hours at 0 °c, -10 °c and -20 °c on Φ15 × 300L (40cc into water) copper pipe.
|
|
Vat temperature |
16W standard heater temperature |
12W low power consumption heater temperature |
Heater |
0°c |
181.0 °c |
121.8 °c |
|
-10°c |
173.8 °c |
114.2 °c |
|
|
-20°c |
165.5 °c |
102.9 °c |
|
Pipe |
0°c |
26.0 °c |
26.3 °c |
|
-10°c |
16.8 °c |
17.0 °c |
|
|
-20°c |
5.9 °c |
6.1 °c |
|
Water |
0°c |
25.30°c |
26.20 °c |
|
-10°c |
15.60°c |
16.70 °c |
|
|
-20°c |
4.20 °c |
5.50 °c |
Wattage
12 W (normal 16W) 24W (normal 32W) |
Dimension A (mm)
35 mm 70 mm |
![]() |
The dimension of the bracket (R), fit to every size and can be made in copper or aluminium.
Other sizes are also possible upon request.
* Pattented technology